Products

Featured products

Contact us

  • Split Economical DC Inverter Heat Pump (15kW)
  • video

Split Economical DC Inverter Heat Pump (15kW)

-Better cooling/heating capacity, A+++ ErP label -LCD large screen control panel -380V power supply -Cheaper, but equally good performance
  • SUOHER
  • China
  • 35 working days
  • 5000 units per month

       Split Economical DC Inverter Heat Pump (15kW)


Installation Requirements for Split Heat Pump (Split Heat Pump): ‌‌ Outdoor Unit ‌: Must be installed in a well-ventilated, unobstructed location at least 50cm away from walls, avoiding direct sunlight or heat source interference. ‌ Indoor Unit ‌: Requires reserved maintenance space (e.g., ceiling inspection port), unobstructed supply/exhaust vents to ensure smooth airflow circulation. ‌ Installation environment ‌ walls must support outdoor unit weight (typically requires concrete or steel structure support). Refrigerant piping must be professionally welded, with pipe length generally not exceeding 50 meters and height difference not exceeding 30 meters. Requires independent power supply (220V/380V) with residual current device (RCD). Condensate pipe should maintain 8° slope to prevent reverse flow or blockage. ‌ Split Heat Pump Advantages: ‌‌ High energy efficiency, ‌ pipeline-free design reduces energy loss (traditional central air conditioning pipes lose up to 30%), achieving 15.2-35 SEER2 efficiency ratio. Supports zoned control for independent room temperature adjustment, reducing energy consumption in vacant areas‌. ‌ flexibility and convenience: Requires air duct installation, suitable for retrofitting old homes or small spaces (e.g., apartments, room extensions). Installation requires only 3-inch wall opening, allowing outdoor unit to be installed up to 50 meters away from indoor unit‌. ‌ dual-purpose: Cooling in summer, heating in winter (through heat pump reverse cycle). Some models support hot water supply (e.g., air-water heat pump)‌. ‌ Environmental and Comfort: Reduces carbon emissions by ‌using low GWP refrigerants like R32‌. Low operating noise (some models ≤40dB), precise temperature control‌. Requires auxiliary heating in extreme low temperatures (-25℃ or below)‌. Regular maintenance is required to maintain efficiency, such as cleaning filters and checking refrigerant levels.

High quality Chinese brand parts are used to replace international famous brands. The performance remains unchanged and the price is 20% - 30% cheaper than other models.

If the price of traditional models does not meet your expectations, economical models will be your better choice.

Strong cooling/heating capacity, supporting large area temperature regulation and hot water demand.

Applicable to beauty salons, barbershops, hotels, gyms and other commercial places.


ERP certification is the energy efficiency certification in the European market.

EU regulations: All electrical and electronic products sold in Europe must meet the requirements of ERP energy efficiency test or ERP certification (energy saving requirements for products related to energy consumption in Europe)


Our main products such as DC inverter series have reached the highest level of ERP, A++level.

A+++indicates that the product has the highest energy efficiency level and the best energy-saving effect when used.

35 degrees represents the floor heating conditions, while 55 degrees represents the radiator conditions, that is, users can obtain higher energy efficiency under different operating conditions.


  • How does the Air Source Heat Pump work?

    The heat from the sun is stored in the air year after year so that we can get a constant source of naturally renewed energy. This stored energy is ideal heat source for your daily domestic heating demand. The air source heat pump collects heat from the solar energy stored in the air. The heat is collected and carried by refrigerant and then converts it into high grade heat to be released to your house by underfloor heating system or radiator and into your domestic hot water tank. ● The solar energy stored in the nature can be brought up by a heat exchanger called evaporator. Here the refrigerant absorbs the solar energy and turns into very low temperature gas. ● The gas refrigerant is compressed and turns into very hot and high pressure gas, then the heat is transferred to the water-based heating system in the house by a condenser. ● Then the refrigerant reverts to low pressure liquid and is ready to collect new solar energy.
  • How long is the warranty period of the heat pump?

    We promise that if the main parts of the product are damaged due to quality or process problems within 24 months, we will guarantee the product.
  • Does the heat pump cause pollution?

    The heat pump will not emit any pollutants during operation, but attention should be paid to equipment maintenance to avoid refrigerant leakage.
  • How do I choose the most suitable heat pump model?

    Customers can read our product catalog, browse different product introductions, and then decide which one to choose.
  • How many dB is the noise when the heat pump is running?

    The operating noise of different models varies greatly, from about 30 to 60 dB. Here are some examples: -30dB is similar to the voice of human whispers. -40dB is similar to the sound of refrigerator operation. -60dB is similar to the voice of normal conversation.
  • Why does the copper radiator in the product have some scars and distortions?

    Please don't worry about this problem. Copper is a very soft metal. The copper sheet on the parts will inevitably be squeezed and impacted during the transportation of materials and parts, resulting in some dents or minor scars, which will not affect the performance and service life of the product.

Related Products

Get Quote

top
1.666210s