Products

Featured products

Contact us

  • 40kW DC inverter swimming pool heat pump
  • 40kW DC inverter swimming pool heat pump
  • 40kW DC inverter swimming pool heat pump
  • 40kW DC inverter swimming pool heat pump
  • video

40kW DC inverter swimming pool heat pump

Uses variable frequency compressor, titanium pipe heat exchanger, intelligent controller with Wifi function, can adjust compressor operate speed according to ambient temperature and water temperature, excellent performance and high COP
  • suoher
  • China

How to choose swimming pool heat pump

The constant temperature of the swimming pool only requires a water outlet temperature of about 28 ℃ (adult pool standard), while ordinary heating heat pumps usually require a temperature of over 55 ℃. Specialized models have higher energy efficiency (COP can reach 5:1 or more) and avoid energy waste. Titanium metal heat exchangers are essential components that can resist chloride ion corrosion in pool water and extend their lifespan.


swimming pool heat pump

 

DC inverter heat pump can automatically adjust power according to water temperature, saving more than 30% energy compared to fixed frequency. DC inverter heat pump runs at high speed during initial heating and maintains low consumption during constant temperature, while reducing compressor losses.

The swimming pool heater has a wide temperature range (such as -20 ℃~43 ℃) and is suitable for both northern and southern climates. Constant temperature swimming pool equipment - in detail, air source heat pumps are different from pool air source constant temperature heat pumps and heating air source heat pumps.  

DC inverter heat pump

 

How to choose a DC inverter heat pump for a thermostatic swimming pool?  

Prioritize selecting DC inverter heat pumps with first level energy efficiency. The operating cost of air source heat pumps is only 1/4 to 1/3 of that of electric heating, and their long-term economic benefits are significant. Northern low-temperature regions: Optional low-temperature enthalpy increasing technology or auxiliary electric heating to ensure stable operation below -15 ℃. Southern warm regions: can be paired with solar heating systems to further reduce energy consumption. Security and intelligent configuration, multiple protection mechanisms.


DC inverter swimming pool heat pump

The design of water and electricity separation, leakage protection, refrigerant high and low voltage protection, and frost prevention function for the swimming pool heat pump are indispensable. Real time monitoring of water temperature, room temperature, and humidity to avoid wall mold or glass condensation caused by high humidity environments. Intelligent control and linkage, optional LCD control panel, supports remote setting of water temperature/humidity thresholds, and automatically switches between dehumidification/heating modes. The per capita fresh air volume should reach 15-30m ³/h, and chlorine containing waste gas should be discharged in a timely manner to ensure air quality.

Key points for installation and maintenance of DC inverter swimming pool heat pump: The unit needs to be ventilated on all sides (double row heat exchange design is optimal), away from obstructions, to ensure heat absorption efficiency. Equipment base shock absorption treatment to reduce noise; The pipeline is connected by brazing to prevent refrigerant leakage. Modular box structure for easy maintenance; The filter screen needs to be easy to disassemble and clean.

swimming pool heat pump

  • How does the Air Source Heat Pump work?

    The heat from the sun is stored in the air year after year so that we can get a constant source of naturally renewed energy. This stored energy is ideal heat source for your daily domestic heating demand. The air source heat pump collects heat from the solar energy stored in the air. The heat is collected and carried by refrigerant and then converts it into high grade heat to be released to your house by underfloor heating system or radiator and into your domestic hot water tank. ● The solar energy stored in the nature can be brought up by a heat exchanger called evaporator. Here the refrigerant absorbs the solar energy and turns into very low temperature gas. ● The gas refrigerant is compressed and turns into very hot and high pressure gas, then the heat is transferred to the water-based heating system in the house by a condenser. ● Then the refrigerant reverts to low pressure liquid and is ready to collect new solar energy.
  • How long is the warranty period of the heat pump?

    We promise that if the main parts of the product are damaged due to quality or process problems within 24 months, we will guarantee the product.
  • Does the heat pump cause pollution?

    The heat pump will not emit any pollutants during operation, but attention should be paid to equipment maintenance to avoid refrigerant leakage.
  • How do I choose the most suitable heat pump model?

    Customers can read our product catalog, browse different product introductions, and then decide which one to choose.
  • How many dB is the noise when the heat pump is running?

    The operating noise of different models varies greatly, from about 30 to 60 dB. Here are some examples: -30dB is similar to the voice of human whispers. -40dB is similar to the sound of refrigerator operation. -60dB is similar to the voice of normal conversation.
  • Why does the copper radiator in the product have some scars and distortions?

    Please don't worry about this problem. Copper is a very soft metal. The copper sheet on the parts will inevitably be squeezed and impacted during the transportation of materials and parts, resulting in some dents or minor scars, which will not affect the performance and service life of the product.

Related Products

Get Quote

top
1.709841s