-Suitable for indoor swimming pools, spas, baths, etc -220V power supply
  • SUOHER
  • China
  • 35 working days
  • 5000 units per month

DC Inverter Swimming Pool Heat Pump (24kW)


Swimming Pool Heat Pump

REMARKS

Swimming Pool Heat Pump, based on the operating condition of 10°C air temperature and the basic situation of the pool, the selection of fixed-frequency heat pump is 60KW, and the variable-frequency heat pump selection is 34kW to meet the initial heating demand. (At 26°C, the heating capacity is 60kW*). To maintain constant temperature throughout the four seasons, the required heating capacities for each season are: Winter: 13.48kW, Spring and Autumn: 11.84kW, Summer: 9.92kW. Not only does there exist a significant difference in operating costs, but as the core equipment for creating a constant temperature experience throughout the four seasons, the service life of the variable-frequency heat pump also affects its operating costs.


The DC Inverter Swimming Pool Heat Pump operates in a 120% super-frequency mode during the initial heating phase to rapidly warm the pool. Once the preset temperature is reached, it automatically maintains operation at an average 30%-50% rate, intelligently regulating the compressor's frequency to "avoid unnecessary work". Additionally, the heat pump features Mitsubishi's DC inverter compressor, offering high efficiency, low vibration, and quiet operation, thereby extending its service life. Whether aligning with the "Dual Carbon" policy or prioritizing year-round swimming comfort for villa owners, this energy-efficient, silent, and smart inverter heat pump stands as the top choice for pool owners. We will continue to advance inverter technology and enhance smart operation experiences for pool equipment, enabling users to enjoy year-round inverter hot spring pool life.


The DC Inverter Heat Pump operates within a temperature range of-10°C to 43°C. Under test conditions with ambient temperatures of 24°C and 19°C, and inlet water temperatures of, the air-source heat pump's operational range of-10°C to 43°C demonstrates its adaptability to wide ambient temperature variations, though its low-temperature limit should be noted. If winter ambient temperatures frequently drop below-10°C, the equipment may require auxiliary electric heating, which could impact energy efficiency. Test conditions: Ambient temperatures in winter typically remain above-10°C, allowing normal operation of this device. For mid-high latitude regions (e.g., northern areas): If winter temperatures are consistently low For more extreme environments (e.g., -40°C extreme cold or high-temperature scenarios), consider using cascade technology or two-stage compression heat pump products, which can operate stably within a wider temperature range of-35°C to 45°C or beyond.



  • How does the Air Source Heat Pump work?

    The heat from the sun is stored in the air year after year so that we can get a constant source of naturally renewed energy. This stored energy is ideal heat source for your daily domestic heating demand. The air source heat pump collects heat from the solar energy stored in the air. The heat is collected and carried by refrigerant and then converts it into high grade heat to be released to your house by underfloor heating system or radiator and into your domestic hot water tank. ● The solar energy stored in the nature can be brought up by a heat exchanger called evaporator. Here the refrigerant absorbs the solar energy and turns into very low temperature gas. ● The gas refrigerant is compressed and turns into very hot and high pressure gas, then the heat is transferred to the water-based heating system in the house by a condenser. ● Then the refrigerant reverts to low pressure liquid and is ready to collect new solar energy.
  • How long is the warranty period of the heat pump?

    We promise that if the main parts of the product are damaged due to quality or process problems within 24 months, we will guarantee the product.
  • Does the heat pump cause pollution?

    The heat pump will not emit any pollutants during operation, but attention should be paid to equipment maintenance to avoid refrigerant leakage.
  • How do I choose the most suitable heat pump model?

    Customers can read our product catalog, browse different product introductions, and then decide which one to choose.
  • How many dB is the noise when the heat pump is running?

    The operating noise of different models varies greatly, from about 30 to 60 dB. Here are some examples: -30dB is similar to the voice of human whispers. -40dB is similar to the sound of refrigerator operation. -60dB is similar to the voice of normal conversation.
  • Why does the copper radiator in the product have some scars and distortions?

    Please don't worry about this problem. Copper is a very soft metal. The copper sheet on the parts will inevitably be squeezed and impacted during the transportation of materials and parts, resulting in some dents or minor scars, which will not affect the performance and service life of the product.