Products

Featured products

Contact us

  • Monoblock DC Inverter Heat Pump (15kW-18kW)
  • Monoblock DC Inverter Heat Pump (15kW-18kW)
  • Monoblock DC Inverter Heat Pump (15kW-18kW)
  • Monoblock DC Inverter Heat Pump (15kW-18kW)
  • video

Monoblock DC Inverter Heat Pump (15kW-18kW)

-Stronger heating/cooling capacity -Suitable for families with more than 5 people or for commercial use -380V/3PH/50Hz -Environmentally friendly refrigerant.
  • SUOHER
  • China
  • 35 working days
  • 5000 units per month

               Monoblock DC Inverter Heat Pump (15kW-18kW)

Based on the selection requirements for pool heat pumps and leveraging DC inverter technology advantages, the core selection parameter for DC inverter heat pumps is heating capacity matching ‌ 10cubic meter of pool temperature increase (from 26℃ to 40℃). A heating capacity of ≥20kW is required, with a recommended model of 25kW to address heat loss. Air-to-water heat pumps‌ with COP ‌ priority should be chosen when ≥5.0.

These fully DC-inverter models achieve high-efficiency heating in 30℃ ambient temperatures‌ through intelligent compressor speed regulation, saving over 30% energy compared to fixed-frequency equipment‌. Key technical features: ‌wide operating temperature range‌ supporting-15℃ to 45℃ ambient temperatures for year-round stable operation; ‌titanium alloy heat exchangers‌ resistant to chloride ion corrosion to extend pool-specific heat pump lifespan‌‌; smart defrosting‌ reduces frost formation in humid environments while maintaining continuous heating capacity‌ Pool constant-temperature "more energy-efficient" selection: choose three-in-one dehumidifying heat pumps with variable frequency.

Installation and maintenance recommendations‌ include windproof and waterproof designs; ‌outdoor installations require IPX4-rated enclosures‌‌ Implement time-of-use operation‌ utilizing off-peak electricity for heating, reducing energy costs by over 30%. Maintenance cycle‌: Clean evaporator fins quarterly and check refrigerant pressure annually. Specific models should be determined based on local grid capacity and installation space. DC Inverter Heat Pump (Direct Current Variable Frequency Heat Pump) is an energy-efficient temperature control device.‌ The pool constant-temperature system‌‌ operates with energy-saving precision,‌ using DC inverter technology to precisely regulate compressor speed and dynamically output heat based on actual pool load, achieving over 30% energy savings compared to traditional fixed-frequency equipment‌. ‌Silent operation‌: Equipped with a DC inverter fan, noise reduction of 20%, suitable for high-noise sensitive environments‌. ‌

Home and commercial heating:‌‌ Air-source heat pumps‌ utilize reverse Carnot cycle to extract heat from air, providing efficient heating for residential or commercial spaces with COP (Coefficient of Performance) reaching above‌ 5.2. ‌Smart control‌ supports remote monitoring and adaptive adjustment, adapting to varying thermal demands‌ throughout different time periods. ‌

Industrial and special scenarios, High-temperature heat pumps‌ are designed for industrial processes requiring high-temperature heating (e.g., above 80℃°C), achieved through multi-stage compression technology. ‌Dehumidification constant temperature: Integrated dehumidification function maintains balanced temperature and humidity in humid environments such as swimming pools and greenhouses‌.

  • How does the Air Source Heat Pump work?

    The heat from the sun is stored in the air year after year so that we can get a constant source of naturally renewed energy. This stored energy is ideal heat source for your daily domestic heating demand. The air source heat pump collects heat from the solar energy stored in the air. The heat is collected and carried by refrigerant and then converts it into high grade heat to be released to your house by underfloor heating system or radiator and into your domestic hot water tank. ● The solar energy stored in the nature can be brought up by a heat exchanger called evaporator. Here the refrigerant absorbs the solar energy and turns into very low temperature gas. ● The gas refrigerant is compressed and turns into very hot and high pressure gas, then the heat is transferred to the water-based heating system in the house by a condenser. ● Then the refrigerant reverts to low pressure liquid and is ready to collect new solar energy.
  • How long is the warranty period of the heat pump?

    We promise that if the main parts of the product are damaged due to quality or process problems within 24 months, we will guarantee the product.
  • Does the heat pump cause pollution?

    The heat pump will not emit any pollutants during operation, but attention should be paid to equipment maintenance to avoid refrigerant leakage.
  • How do I choose the most suitable heat pump model?

    Customers can read our product catalog, browse different product introductions, and then decide which one to choose.
  • How many dB is the noise when the heat pump is running?

    The operating noise of different models varies greatly, from about 30 to 60 dB. Here are some examples: -30dB is similar to the voice of human whispers. -40dB is similar to the sound of refrigerator operation. -60dB is similar to the voice of normal conversation.
  • Why does the copper radiator in the product have some scars and distortions?

    Please don't worry about this problem. Copper is a very soft metal. The copper sheet on the parts will inevitably be squeezed and impacted during the transportation of materials and parts, resulting in some dents or minor scars, which will not affect the performance and service life of the product.

Related Products

Get Quote

top
1.608061s